Because of how BTT has their endstop filtering done on their boards it can make the EZABL not function correctly when connected to the Z endstop. You should use the “Probe” port instead of the “Z-STOP” port for connecting to the EZABL signal side.
Duet doesn’t have a built in M48 gcode command. You can make your own by making a file in the SYS (aka system) folder named M48.g. Paste the below text into that file and save it. Then send M48 to your printer. It will take 10 probe readings and give you the deviation that the […]
Wiring Info Because of how BTT has their endstop filtering done on their boards it can make the EZABL not function correctly when connected to the Z endstop. You should use the “Probe” port instead of the “Z-STOP” port for connecting to the EZABL signal side. Firmware Settings You will still use the recommended EZABL […]
About the M48 Test One of the first things you should if you are having issues is check how well its working by using the M48 command to test it. If your M48 test results in a value of 0.01 or lower for the standard deviation then the probe is working and something else on […]